高粘度非ニュートン流体の気泡除去に関する研究成果がJ. Taiwan Inst. Chem. Eng.誌にオープンアクセス論文として掲載されました。
論文タイトルは、“Bubble removal from highly viscous non-Newtonian fluids by utilizing cavity formation in a mixing vessel”です。
高粘度非ニュートン流体に含まれる微細な気泡を、撹拌翼の背面に形成される気体の集積部(cavity、キャビティ)を利用して除去する研究成果が、 Journal of the Taiwan Institute of Chemical Engineers に掲載されました。 本研究では、気泡をキャビティへ輸送する槽内流動の重要性を明らかにするとともに、 新たに設計したAdvanced Mixing(AM)翼を用い、600 rpm・10分間の撹拌で、画像解析に基づく気泡除去率98%超を得ました(0.25 wt% CVP水溶液)。
論文情報 / Publication
- Title
- Bubble removal from highly viscous non-Newtonian fluids by utilizing cavity formation in a mixing vessel
- Authors
- Deng XUEER, Rikuto DENAGA, Kaho IKEDA, Yoshihito KATO, Shinsuke ASAYAMA, Norihiro MORIKAWA, Hyun-Gi KOH, and Haruki FURUKAWA
- Affiliations
- Nagoya Institute of Technology (Japan); Nippon Sosey Kogyo Co., Ltd. (Japan); Hongik University (Republic of Korea)
- Journal
- Journal of the Taiwan Institute of Chemical Engineers (2026), Article 107084
- Publication status
- Article in Press / Corrected Proof (volume and issue not yet specified)
- Accepted
- 9 November 2026
- DOI
- 10.1016/j.jtice.2026.107084
- Access
- Open Access(Creative Commons Attribution 4.0 International, CC BY 4.0)
研究背景と目的
高粘度の高分子溶液やスラリーに混入した微細な気泡は、製品品質や性能を低下させる要因となります。特に降伏応力を示す非ニュートン流体では、気泡の浮力による上昇が妨げられるため、脱泡が困難です。真空脱泡や超音波などの方法が用いられていますが、液の物性や装置規模によって適用が制限される場合があります。
本研究では、通常は気液撹拌で観察される「撹拌翼背面のキャビティ形成」を、微細気泡の回収・合一に積極的に利用する脱泡方法を検討しました。さらに、翼形状と槽内流動が脱泡性能に及ぼす影響を調べました。
脱泡の原理:cavityとcavernの役割
Cavity(キャビティ):翼背面の圧力低下によって形成される、気泡を含む気体の集積部。微細気泡が集まり、合一する場所として機能します。
Cavern(キャバーン、流動領域):降伏応力を示す流体で撹拌翼の周囲に形成される、流体が実質的に動いている領域。槽内に分散した気泡を翼近傍のキャビティまで輸送します。
撹拌中は、cavern内の流れによって微細気泡が翼背面のcavityへ運ばれ、そこで集積・合一します。撹拌停止後にcavityが翼から離れ、浮力で液面まで上昇することで気泡が除去されます。したがって、安定したcavityの形成と、槽内からcavityへの気泡輸送の両立が重要です。
研究方法
モデル流体として、Herschel–Bulkleyモデルに従う流動特性を示す透明なカルボキシビニルポリマー(carboxyvinyl polymer, CVP)0.25 wt%水溶液を使用しました。内径150 mm、液深150 mmの円筒形撹拌槽で、Rushton turbine、concave turbine、それらの二段翼構成、および脱泡用に設計したAM翼を比較しました。高粘度条件の追加検証には0.50 wt% CVP水溶液を使用しました。
撹拌前後の気泡分布をスリット光による断面撮影で観察し、槽の周方向4位置(0°、45°、90°、135°)の画像から気泡に対応する面積割合を求め、気泡除去率を評価しました。撹拌時間と回転数の影響に加え、cavity形成とcavernの広がりを観察しました。
注:論文の「気泡除去率」は、断面画像の気泡面積割合の減少から計算した指標です。三次元の気相体積率を直接測定した値ではありません。
主な研究成果
- 従来のRushton turbineで約90%の除去:気泡除去率は撹拌開始後に増加し、約1分でほぼ一定になりました。従来翼では約90%が到達水準でした(論文Fig. 5、Fig. 8、結論)。
- 単純な高速化には限界:Rushton turbineの気泡除去率は約900 rpmまで増加しましたが、1000 rpmでは自由表面から新たな気泡が巻き込まれ、除去率が低下しました。また、ドーナツ状の孤立混合領域が形成されると、気泡がcavityへ到達しにくくなりました(Fig. 8–11)。
- 翼形状の改良だけでは不十分:二段翼や凹面翼を使用すると性能は改善しましたが、従来翼の中で最も良好だった二段凹面翼でも、気泡除去率は約90%を超えませんでした(Fig. 14)。
- AM翼で98%超:大きな流動領域を確保しつつcavityを形成するよう設計したAM翼では、0.25 wt% CVP水溶液に対し、600 rpm、10分間の撹拌で画像解析に基づく気泡除去率が98%を超えました(Fig. 16)。なお、1分間の撹拌では他の翼に対する顕著な優位性は見られず、撹拌時間の延長に伴って除去率が向上しました。
- より高粘度の条件でも有効:0.50 wt% CVP水溶液による比較でも、AM翼は従来翼より高い気泡除去率を維持しました(Fig. 17)。この条件で98%超と報告したものではありません。
本研究の意義と今後の課題
本研究は、撹拌翼の背面に形成されるcavityを気泡の回収場所として利用する方法を提示し、脱泡性能が「翼背面での気泡回収」と「槽全体からの気泡輸送」の両方に左右されることを示しました。既存の撹拌装置を利用して追加の脱泡装置なしに気泡を除去できる可能性があり、高粘度高分子溶液やスラリーの製造工程に向けた設計指針となります。
一方、今回の実験は特定のCVP水溶液と撹拌槽で行われたものです。論文では、エネルギー効率の定量評価、スケールアップ特性、異なるレオロジー特性をもつ流体への適用を今後の課題としています。
Research overview
Removing fine bubbles from highly viscous, yield-stress non-Newtonian fluids is challenging because bubble rise can be strongly suppressed. This study investigated a degassing approach based on gas-filled cavities formed behind rotating impeller blades. Bubbles dispersed in the liquid are transported through the flowing cavern, collected and coalesced within the blade cavities, and released to the free surface after agitation stops.
Experiments employed 0.25 wt% aqueous carboxyvinyl polymer (CVP) as a model Herschel–Bulkley fluid. Bubble removal was quantified from changes in image-based bubble area fractions measured at four circumferential positions. Conventional Rushton turbines, concave turbines, dual-impeller arrangements, and a redesigned Advanced Mixing (AM) impeller were compared. A 0.50 wt% CVP solution was also tested.
Key findings
- A conventional Rushton turbine achieved approximately 90% image-based bubble removal within about 1 min, whereas conventional dual-stage and concave turbine modifications remained limited to approximately 90%.
- Higher rotational speeds initially increased bubble removal, but excessive rotation promoted free-surface air entrainment and the formation of a doughnut-shaped isolated mixing region, reducing transport of bubbles toward the blade cavities.
- The redesigned AM impeller achieved an image-based bubble removal rate exceeding 98% after 10 min at 600 rpm in 0.25 wt% CVP solution; its performance increased with mixing time.
- The AM impeller maintained superior bubble removal performance relative to the selected conventional impellers in the higher-viscosity 0.50 wt% CVP solution.
Significance and limitations
Effective cavity-based degassing requires both stable gas collection behind the blades and sustained transport of bubbles through the cavern. This provides an impeller-design concept for removing entrained bubbles using mixing equipment already employed in processing viscous fluids. Quantitative assessment of energy efficiency, scale-up, and applicability to other rheological systems remains a subject for future work.
Keywords / キーワード
Bubble removal; Degassing; Cavity formation; Cavern; Highly viscous non-Newtonian fluid; Yield-stress fluid; Herschel–Bulkley fluid; Mixing vessel; Advanced Mixing (AM) impeller; Rushton turbine; Carboxyvinyl polymer (CVP)
脱泡;気泡除去;キャビティ形成;キャバーン;高粘度非ニュートン流体;降伏応力流体;Herschel–Bulkleyモデル;撹拌槽;撹拌翼;AM翼;Rushton turbine;カルボキシビニルポリマー
Citation
Deng XUEER, Rikuto DENAGA, Kaho IKEDA, Yoshihito KATO, Shinsuke ASAYAMA, Norihiro MORIKAWA, Hyun-Gi KOH, and Haruki FURUKAWA (2026). “Bubble removal from highly viscous non-Newtonian fluids by utilizing cavity formation in a mixing vessel.” Journal of the Taiwan Institute of Chemical Engineers, Article 107084, Article in Press. DOI: 10.1016/j.jtice.2026.107084.
Additional information
本論文はCC BY 4.0ライセンスによるオープンアクセス論文です。研究結果の図表・詳しい実験条件は、以下の出版社ページからご確認ください。
Publisher / DOI: https://doi.org/10.1016/j.jtice.2026.107084
出典:Deng XUEER et al. (2026), 論文本文 pp. 1–9(特にFig. 8–18およびConclusions)。